Inhaltsverzeichnis

Seite 1 - ADDENDUM

Installation Operation Maintenance ADDENDUM Bulletin #: PS-IOM-HYPO2-0111-A

Seite 2

6 8. Description and Operation 8.1 Principle of Operation Reciprocating metering pumps are used with a wide variety of chemicals, such as sodium hy

Seite 3 - Table of Contents

7 9. Maintenance 9.1 Maintenance Notes The O-ring seals used in the check valve and ADV are critical to product containment and pump operation. All

Seite 4 - 1. Conventions

8 6. Remove outer spring from Core Assembly (Seal Kit Assembly) and pull Core Assembly out. 7. Inspect Valve Body for O-rings that

Seite 5 - 2. General Safety

9 10. Install NEW O-ring onto core tube, lubricate with lubricant that is compatible with product being pumped, and reinstall sleeve over Core Tube.

Seite 6 - 5. Retrofit

10 15. Slide Core Tube over core and align to the tabs on the Valve Body. 16. Slide Union Nut over Core Tube and tighten onto Body. Do not

Seite 7 - 6. Overall System Diagram

11 5. Loosen the suction valve tiebar bolts and shift the suction piping slightly to drain any liquid from the reagent head cavity. If the piping is

Seite 8 - 7. Installation

12 PS-IOM-HYPO2-0111-A

Seite 9

iiFACTORY SERVICE POLICY If you are experiencing a problem with your Pulsafeeder pump, first review the IOM, and consult the troubleshooting guide.

Seite 10 - 8. Description and Operation

iiiTable of Contents 1. CONVENTIONS ...

Seite 11 - 9. Maintenance

iv1. Conventions For the remainder of this bulletin, the following Conventions are in effect. A WARNING DEFINES A CONDITION THAT COULD CAUSE DAMAG

Seite 12

1 2. General Safety The Auto De-gas Valve (ADV) was designed as a gas handling/priming aid for operation solely with Pulsafeeder PULSAR® and PULSAR

Seite 13

2 3. Equipment Inspection When you receive your order, check all equipment for:  Completeness against the shipping document / purchase order  Evi

Seite 14

3 6. Overall System Diagram \ Figure 1 The ADV consists of a pressure balanced valve which opens periodic

Seite 15 - 10. Troubleshooting Guide

4 7. Installation 7.1 Location Review the Safety section prior to installing the pump with ADV. It contains information required to properly instal

Seite 16 - PS-IOM-HYPO2-0111-A

2 Install wiring to the unit using a minimum of 18 inches of flexible conduit or cable attached to the auto valve assembly in order to facilitat