Series MP
ELECTRONIC METERING PUMPS
Installation
Operation
Maintenance
Instruction
READ ALL WARNINGS CAREFULLY
BEFORE INSTALLING
Seitenansicht 0
1 2 3 4 5 6 ... 31 32

Inhaltsverzeichnis

Seite 1 - Series MP

Series MP ELECTRONIC METERING PUMPS Installation Operation Maintenance Instruction READ ALL WARNINGS CAREFULLY BEFORE INSTALLING

Seite 2 - SAFETY INSTRUCTIONS

10 PIPING 1. Use provided tubing of specified size for connection. Connect tubing securely to prevent leakage of chemical and the entrance of air.

Seite 3 - TABLE OF CONTENTS

11 WIRING 1. : Risk of electrical shock. This pump is supplied with a three prong grounding type power plug. To reduce risk of electric shock, con

Seite 4 - INTRODUCTION

12 DESCRIPTION OF CONTROLS AND OPERATION INTRODUCTION The pump performs the following functions: Selected Controls - Fixed Rate - External

Seite 5

13 HELPFUL HINTS You can always get to where you want to go simply by accepting or rejecting choices presented. If you find yourself within a menu wh

Seite 6 - PRECAUTIONS FOR OPERATION

14 EXTERNAL PULSE CONTROL - MULTIPLICATION The pump operates as described previously except that incoming pulses are multiplied by a value from 1 to

Seite 7

15 RELAY OFF In all control options the relay remains open at all times. STOP FUNCTION In all control options the relay is normally open and closes w

Seite 8

16 CONTROL REFERENCE SUMMARY CONTROL OPTIONS Fixed Rate Fixed Rate 100% External Pulse Straight Straight Pulse Pulse Storage opti

Seite 9

17 SETTINGS OPTIONS Settings? Flow Verify? Yes=On No=Off Relay Output? Relay-Stop? Relay-Repeat? Rel-No S

Seite 10

18 START UP AND OPERATION POWER All metering pumps are available in 115 volts at 50/60 Hertz, single phase. Optionally 230 volts at 50/60 Hertz, sing

Seite 11

19 STROKE LENGTH ADJUSTMENT  Stroke length can be controlled within 0 to 100% of the diaphragm displacement. (It should be controlled within 20 to

Seite 12 - Selected Controls

2 SAFETY INSTRUCTIONS When using chemical feed pumps, basic safety precautions should always be followed to reduce risk of fire, electric shock, and

Seite 13 - CONTROL OPTIONS

20 OPERATION BY EXTERNAL INPUT SIGNALS: The pump can be controlled by three types of input signals. All are fully isolated from AC input power and fr

Seite 14 - RELAY SETTINGS

21 The pump responds to a 4-20mA signal as follows when the high rate is 100%, the low rate is 0%, the high signal is 20mA and the low signal is 4m

Seite 15

22 OUTPUT RELAY Each pump has the option of being provided with one of two separate normally open output relay options as described below. Relays cl

Seite 16 - CONTROL REFERENCE SUMMARY

23 ADDITIONAL SETTINGS: “Flow Verify?” – used in conjunction with the flow verification meter; to activate this option: Choose: “Settings?”, press

Seite 17

24 MAINTENANCE : Before performing any maintenance or repairs on chemical metering pumps, be sure to disconnect all electrical connections and insur

Seite 18 - START UP AND OPERATION

25 DIAPHRAGM REPLACEMENT Refer to drawings in the back of the manual. 1. When replacing the diaphragm, it’s always a good idea to replace the valve

Seite 19

26 TROUBLESHOOTING PROBLEM PROBABLE CAUSE REMEDY LOSS OF CHEMICAL RESIDUAL 1. Pump setting too low. 2. Scale at injection point 3. Solution contain

Seite 22

29 Specifications Pressure, MAX, PSI/BAR@ GPD/GPH/LPD300/203/.13/11Capacity, MAX, GPD/GPH/LPD@ PSI/BAR500/20.8/189020/1.4Reproducibility, % MAX Capac

Seite 23

3 TABLE OF CONTENTS

Seite 24 - MAINTENANCE

30 REPAIR SERVICE Normally following the instructions in the previous sections of the manual will rectify any pump problems. If, however, after foll

Seite 25

31 Keep-On-Pumping kits that can save you time and money! The manufacturer has built a reputation for superio

Seite 26

32 L9404500-000 PRINTED IN U.S.A. Revision E USA Pulsafeeder, Inc.

Seite 27

4 INTRODUCTION These installation, operation and maintenance instructions cover your electronic metering pump. Refer to the pump nameplate to determi

Seite 28

5  EUROPEAN TECHNICAL FILE LOCATION PO Box 91 Washington NE37 1YH United Kingdom  UNPACKING THE PUMP Check all equipment for com

Seite 29 - Specifications

6 PRECAUTIONS FOR OPERATION Each Electronic Metering Pump has been tested to meet prescribed specifications and safety standards. Proper care in han

Seite 30 - REPAIR SERVICE

7 17. When using pump with pressurized systems, make sure the pressure of the system does not exceed the maximum pressure rating on the pump namepla

Seite 31 - Selecting a KOPkit

8 INSTALLATION, PIPING AND WIRING The metering pump should be located in an area that allows convenient connections to both the chemical storage tank

Seite 32

9 3. The pump can be mounted to a wall as shown in Figure D. A wall mount bracket kit is available which includes all necessary hardware to mount t