21
72-001-02 Rev A
9. TroubleShooting
Blown fuse, circuit breaker.
Replace - eliminate overload.
Open valves, clear other obstructions.
Check power source. Check wiring
diagram.
Ball check valves held open with solids.
Clean – inspect, flush with clear fluid.
Increase suction pressure.
Re-prime, check for leak.
Remove and clean. Replace screen if
necessary.
Stroke adjustment set at zero.
Increase stroke length setting.
Check voltages, frequency, wiring, and
terminal connections. Check nameplate
vs. Specifications.
Check valves worn or dirty
Clean, replace if damaged
Product viscosity too high
Lower viscosity by increasing product
temperature or dilution. Increase pump
and/or piping size
Increase suction pressure.
Delivery gradually
drops.
Clean, replace if damaged.
Check viscosity and other variables.
Supply tank vent plugged.
Increase suction pressure.
Entrained air or gas in product.
Consult factory for suggested venting.
Check voltage and frequency.
Clean, replace if necessary.
Increase discharge pressure to obtain a
minimum pressure difference of 5 pis
from suction to discharge
Delivery higher than
rated.
Suction pressure higher than discharge
pressure.
Install backpressure valve or consult
factory for piping recommendations.
Back pressure valve set too low.
Back pressure valve leaks.
Repair, clean, or replace.